Inlet valve opening pressure test rig for fuel tank

Inlet valve opening pressure test rig for fuel tank

Fuel tank pressure test, safety valve opening pressure test and fuel tank inlet valve opening pressure test rig, gas pump filters

  •  compressed air source, 4.0Mpa (the equipment is taken with the use, the cost of this equipment is not included in the price of the test equipment, the price is adjusted according to the price of the same kind of product).
  • the pressure rate control, 8kPa/min
  • PLC control display,Monitoring gas source, 0 ~ 100kPa 2% Open the pressure control, 0 ~ 100kPa + 1% After the pressure detection, 0 ~ 60kPa + 1% Pressure rate control, 0 ~ 8kPa/min 2%
  • qualified / unqualified alarm and print
  • safety and explosion protection
  • 53 (2) water heating cycle control system (the equipment is taken along with the use,  storage tank calibration methods ,the system charge is not included in the test cost, the price is adjusted according to the price of the same kind of product.

2015年5月29日星期五

Tank system test method

Safety valve opening pressure test the safety performance requirements reference GB18296-2001 national standards 3.1 and 3.4, storage tank calibration methods , the test method reference GB18296-2001 National Standard 4.2. The intake valve opening pressure test referring to the technical requirements of QC / T 644-2000 4.8 industry standards, test methods refer QC / T 644-2000 industry standard 5.6 in. Automatic pressurization system with proportional valve control, water flow control device to control the injection using the rated capacity, electronic fuel dispenser , the use of flow-controllable pumping apparatus pumping. The entire test rig can move, test supporting peripherals used with the check.


2015年5月25日星期一

The third tank system test platform

Plastic fuel tank angle hammer impact test station. The test reference GB18296-2001 National Standard Test Method for z in 4.6. After adding the liquid in the tank rated clamping, storage tank calibration methods , triangular cloud by 15KG weight hammer with impact energy 30J impact Easy lesion; automatic height adjustment angle hammer, hammer adjustable within the angular range of 20J ~ 50J. Entire fixture platform horizontal flip vertically, horizontally to adjust the position of the pendulum. Mass position control can be divided into manual and automatic.

The tank filter media can be recovered. Flow control means for controlling the use of water injection rated capacity. The entire test rig can move, gas station management software test supporting peripherals used with the check.