Fourth test platform of oil tank monitoring system
Fuel tank sealing test rig, tank automation system specific technical requirements of the relevant content of the 4.5 in the 644-2000 QC/T industry standards. Test method reference 644-2000 QC/T industry standard 5.3. The whole system adopts PLC control, vehicle identification system water leakage box adopts high brightness lighting easy detection. The water filtration system can be selected.
Tank gauging system based on volume, the stock of measurement achieved by measuring the level and temperature. In the tank gauging system based on quality, the stock is measured using a liquid measuring hydrostatic liquid column made. In turn metering inventory control or lose, no matter what method, the reliability and accuracy of measuring instruments is very important.
2015年6月1日星期一
2015年5月22日星期五
The second tank system technical indicators
Fuel tank pressure test, gear type pump , the valve opening pressure test and fuel tank inlet valve opening pressure test rig,
(9) Compressed air source: 4.0Mpa (with pick this device, this device is not included in the price of the test equipment, the price according to the market price of similar products to make the appropriate adjustments)
(10) Pressure Rate Control: 8kPa / min
(11) PLC control display, gas station dispensers
Monitoring gas source: 0 ~ 100kPa ± 2%
Opening pressure control: 0 ~ 100kPa ± 1%
After opening pressure detection: 0 ~ 60kPa ± 1%
Pressurization rate control: 0 ~ 8kPa / min ± 2%
(12) pass / fail alarm, submersible fuel pump , print
(13) safety explosion protection
(14) 53 ℃ ± 2 ℃ water heating cycle control system (with pick this device, this system is not included in the trial costs, the price according to the market price of similar products to make the appropriate adjustments)
(9) Compressed air source: 4.0Mpa (with pick this device, this device is not included in the price of the test equipment, the price according to the market price of similar products to make the appropriate adjustments)
(10) Pressure Rate Control: 8kPa / min
(11) PLC control display, gas station dispensers
Monitoring gas source: 0 ~ 100kPa ± 2%
Opening pressure control: 0 ~ 100kPa ± 1%
After opening pressure detection: 0 ~ 60kPa ± 1%
Pressurization rate control: 0 ~ 8kPa / min ± 2%
(12) pass / fail alarm, submersible fuel pump , print
(13) safety explosion protection
(14) 53 ℃ ± 2 ℃ water heating cycle control system (with pick this device, this system is not included in the trial costs, the price according to the market price of similar products to make the appropriate adjustments)
2015年5月20日星期三
Third test platform of oil tank monitoring system
Plastic fuel tank angle hammer impact test station. The test reference GB18296-2001 National Standard Test Method for z in 4.6. After adding the liquid in the tank rated clamping, gas station dispensers triangular cloud by 15KG weight hammer with impact energy 30J impact Easy lesion.
Automatic height adjustment angle hammer, hammer adjustable within the angular range of 20J ~ 50J. Entire fixture platform horizontal flip vertically, horizontally to adjust the position of the pendulum. Mass position control can be divided into manual and automatic.
The tank filter media can be recovered. Flow control means for controlling the use of water injection rated capacity. The entire test rig can move, automatic fuel dispenser test supporting peripherals used with the check.
2015年5月14日星期四
The fourth tank gauging system test platform
Fuel tank tightness test station. Specific technical requirements refer QC / T 644-2000 industry standards relevant content 4.5. Test methods refer QC / T 644-2000 industry standard 5.3. The system adopts PLC control, submersible fuel pump underwater leak box is easy to detect high-intensity lighting. Water circulation filtration system alternative, diesel pump manufacturers .
2015年5月11日星期一
The second tank gauging system test platform
Fuel tank pressure test, gas station dispensers , the valve opening pressure test and fuel tank inlet valve opening pressure test rig. Safety fuel tank pressure test requirements of 3.6, 3.7 reference GB18296-2001 national standards, test methods reference GB18296-2001 national standards 4.4, 4.5 items.
Fuel tank pressure test points test two tests and a metal tank plastic tank. Plastic fuel tank pressure test temperature is very warm. Automatic pressurization system with proportional valve control, fuel dispensing nozzles , water flow control device to control the use of implantation rated capacity. After two trials normal temperature.
Fuel tank pressure test points test two tests and a metal tank plastic tank. Plastic fuel tank pressure test temperature is very warm. Automatic pressurization system with proportional valve control, fuel dispensing nozzles , water flow control device to control the use of implantation rated capacity. After two trials normal temperature.
2015年5月4日星期一
Fuel tank leak detection equipment, production lines acclaim
The company in 2001 for the German KOTAS manufactures a fuel tank leak detection equipment C6 Audi production line, fuel card management system , the use of PLC and computer intelligent automatic detection of qualified and unqualified sorting intelligent storage printing and pneumatic controls have been well received in Germany. Japan seized the wet sensor, in the case of the Japanese staff can not be timely to the site, we solved the installation.
Thus, the German side twice in person to visit our company, but also a set of customized production line leak detection PQ35 contract we completed in two months time and acceptance. For this cooperation project with your company, you will learn to make equipment for the German KOTAS system experience, mechanical fuel level gauge , combined with domestic and foreign products advantages for your company to make qualified satisfaction.
Thus, the German side twice in person to visit our company, but also a set of customized production line leak detection PQ35 contract we completed in two months time and acceptance. For this cooperation project with your company, you will learn to make equipment for the German KOTAS system experience, mechanical fuel level gauge , combined with domestic and foreign products advantages for your company to make qualified satisfaction.
2015年4月28日星期二
Water level meter liquid level and automatic tank gauge systems
Water meter automatic interpretation monitoring system guarantees the safe production of the boiler, boiler water level automatic control possible. In industrial production,automated fuel management system , in order to ensure safety, we must grasp the internal boiler water level data.
However, due to the opaque boiler, can not directly observe the inside water level, in practice,mechanical fuel level gauge usually the boiler water level meter and connected into a closed loop, according to the principle of communicating vessels, the liquid level is the level meter of the water level inside the boiler.
2015年4月24日星期五
Water meter automatic interpretation monitoring system
In order to solve the industrial production of remote monitoring of the water level inside the boiler, this paper designed a water meter automatic interpretation of surveillance systems,oil tank monitoring system and implement the core components of this system, namely embedded video processing platform. Based on the proposed multi-space, the water level meter multi-wavelet transform algorithm to interpret the simulation test, the method is applied to the interpretation of the system to improve the level instrument to achieve a real-time monitoring and automatic interpretation of results.
Experimental results show that the system can effectively identify water level meter red and green stripe cut-off point in a complex background monitoring,mechanical fuel level gauge , so that the water level is calculated to determine the location and height of the water level accurately and efficiently.
2015年4月21日星期二
Oil tank monitoring system use 3G Technology
Automotive fuel tank detection system adopts international advanced 3G network technology, fuel dispensing pump real-time monitoring through the car GPS terminal change fuel vehicles can generate custom reports or historical periods oil change oil graphs visually reflects the normal amount of oil consumed and abnormal fuel consumption and insufficient number of other phenomena, accurately determine the GPS vehicle fuel consumption,mechanical fuel level gauge the fuel consumption reached a high level of management, the occurrence of adverse events DU cut.
2015年4月17日星期五
Hydraulic oil tank monitoring system
The present invention relates to a oil tank monitoring system , in particular to a hydraulic oil monitoring system. Including the tank, pump I, analysis and processing unit I, analysis and processing unit II, filtration devices, the main pipeline, the main pipe is connected to the tank, the tank is connected to the pump I, I and the hydraulic pump the analysis processing means I connected one end of the filter device with the analysis processing device I connected to the other end of the filter device and the analysis processing means connected II, II device connected to the main pipe on the analysis. The beneficial effects of the
present invention is that the system is simple,mechanical fuel level gauge , easy to operate, real-time monitoring of oil contamination, while oil pollution treatment, inspection and maintenance of equipment in a timely manner.
2015年4月14日星期二
Vibration method based power transformer on-line monitoring system
Safe operation of the power system is the people's livelihood priority, and power transformer fault is a major cause electrical safety hazards, therefore,oil tank monitoring system study the power transformer monitoring system is important. Transformers detection methods currently used to detect the offline and online can be divided into two kinds of monitoring, which does not require a transformer on-line monitoring is stopped and can more accurately detect problems in transformer operation.
Traditional transformer on-line monitoring system focused on the electrical characteristics while ignoring the influence of mechanical properties,automated fuel management system , there is no comprehensive monitoring parameters and other issues. Vibration method based transformer on-line monitoring system is in operation by measuring the vibration signal of the transformer tank surface can effectively respond to the state of the process running the transformer core and windings, which is a promising approach.
2015年4月11日星期六
Tank level indication and alarm system design
In order to facilitate the operator to observe the lubrication of mine hoist, a new oil pressure and fuel tank level indication and alarm system design, gives the overall structure of the system,electronic fuel dispenser , pressure transmitters and level transmitter selection, structure and technical specifications of the sound and light alarm and display device works practical application shows that the system is easy to set upper and lower limits, reliable,which can display oil pressure and fuel tank level signal ( tank level controller )at the console intuitive and convenient.
2015年4月2日星期四
The low performance of mechanical tank gauging system maintenance problems
Because of budget constraints, gas station management system , some factories continue to suffer because the communication constraints and low performance of mechanical storage tank liquid level meter and cause maintenance problems.
Now the intelligent wireless technology, you need not automation system ( automated fuel management system )of radar based on Raptor tank for long distance signal line can be installed new.
This will save materials, reduce the labor cost and the engineering design and project
fundamentally execution time.
订阅:
博文 (Atom)

.jpg)









