Tank gauging system based on volume, the stock of measurement achieved by measuring the level and temperature. In the tank gauging system based on quality, the stock is measured using a liquid measuring hydrostatic liquid column made. In turn metering inventory control or lose, no matter what method, the reliability and accuracy of measuring instruments is very important.
2015年5月29日星期五
Tank system test method
Safety valve opening pressure test the safety performance requirements reference GB18296-2001 national standards 3.1 and 3.4, storage tank calibration methods , the test method reference GB18296-2001 National Standard 4.2. The intake valve opening pressure test referring to the technical requirements of QC / T 644-2000 4.8 industry standards, test methods refer QC / T 644-2000 industry standard 5.6 in. Automatic pressurization system with proportional valve control, water flow control device to control the injection using the rated capacity, electronic fuel dispenser , the use of flow-controllable pumping apparatus pumping. The entire test rig can move, test supporting peripherals used with the check.
2015年5月27日星期三
Plastic fuel tank angle hammer impact test
(1) Angle hammer Specifications, Triangle hammer 15kg
(2) Impact energy, 30J
(3) pressure control, 0 ~ 100kPa ± 1%
(4) pressure detection, 0 ~ 100kPa ± 1%
(5) the impact of position / rotation clamping system
(6) the impact hammer lift system
(7) The impact shield, automated fuel management system
(8) tank recovery media filtration system
Plastic fuel tank above angle hammer impact test needs to draw domestic and foreign experience in related products and make appropriate adjustments based on customer requirements , fuel card management system
(2) Impact energy, 30J
(3) pressure control, 0 ~ 100kPa ± 1%
(4) pressure detection, 0 ~ 100kPa ± 1%
(5) the impact of position / rotation clamping system
(6) the impact hammer lift system
(7) The impact shield, automated fuel management system
(8) tank recovery media filtration system
Plastic fuel tank above angle hammer impact test needs to draw domestic and foreign experience in related products and make appropriate adjustments based on customer requirements , fuel card management system
2015年5月25日星期一
The third tank system test platform
Plastic fuel tank angle hammer impact test station. The test reference GB18296-2001 National Standard Test Method for z in 4.6. After adding the liquid in the tank rated clamping, storage tank calibration methods , triangular cloud by 15KG weight hammer with impact energy 30J impact Easy lesion; automatic height adjustment angle hammer, hammer adjustable within the angular range of 20J ~ 50J. Entire fixture platform horizontal flip vertically, horizontally to adjust the position of the pendulum. Mass position control can be divided into manual and automatic.
The tank filter media can be recovered. Flow control means for controlling the use of water injection rated capacity. The entire test rig can move, gas station management software test supporting peripherals used with the check.
The tank filter media can be recovered. Flow control means for controlling the use of water injection rated capacity. The entire test rig can move, gas station management software test supporting peripherals used with the check.
2015年5月22日星期五
The second tank system technical indicators
Fuel tank pressure test, gear type pump , the valve opening pressure test and fuel tank inlet valve opening pressure test rig,
(9) Compressed air source: 4.0Mpa (with pick this device, this device is not included in the price of the test equipment, the price according to the market price of similar products to make the appropriate adjustments)
(10) Pressure Rate Control: 8kPa / min
(11) PLC control display, gas station dispensers
Monitoring gas source: 0 ~ 100kPa ± 2%
Opening pressure control: 0 ~ 100kPa ± 1%
After opening pressure detection: 0 ~ 60kPa ± 1%
Pressurization rate control: 0 ~ 8kPa / min ± 2%
(12) pass / fail alarm, submersible fuel pump , print
(13) safety explosion protection
(14) 53 ℃ ± 2 ℃ water heating cycle control system (with pick this device, this system is not included in the trial costs, the price according to the market price of similar products to make the appropriate adjustments)
(9) Compressed air source: 4.0Mpa (with pick this device, this device is not included in the price of the test equipment, the price according to the market price of similar products to make the appropriate adjustments)
(10) Pressure Rate Control: 8kPa / min
(11) PLC control display, gas station dispensers
Monitoring gas source: 0 ~ 100kPa ± 2%
Opening pressure control: 0 ~ 100kPa ± 1%
After opening pressure detection: 0 ~ 60kPa ± 1%
Pressurization rate control: 0 ~ 8kPa / min ± 2%
(12) pass / fail alarm, submersible fuel pump , print
(13) safety explosion protection
(14) 53 ℃ ± 2 ℃ water heating cycle control system (with pick this device, this system is not included in the trial costs, the price according to the market price of similar products to make the appropriate adjustments)
2015年5月20日星期三
Third test platform of oil tank monitoring system
Plastic fuel tank angle hammer impact test station. The test reference GB18296-2001 National Standard Test Method for z in 4.6. After adding the liquid in the tank rated clamping, gas station dispensers triangular cloud by 15KG weight hammer with impact energy 30J impact Easy lesion.
Automatic height adjustment angle hammer, hammer adjustable within the angular range of 20J ~ 50J. Entire fixture platform horizontal flip vertically, horizontally to adjust the position of the pendulum. Mass position control can be divided into manual and automatic.
The tank filter media can be recovered. Flow control means for controlling the use of water injection rated capacity. The entire test rig can move, automatic fuel dispenser test supporting peripherals used with the check.
2015年5月18日星期一
The first tank system specifications, the gas cap tightness test
(1) water tank and pumping system flow control device: full rated water ± 95% (with the check with the use of this system, this system does not cost, automatic fuel dispenser ,the test equipment is included in the cost, the price according to the market price of similar products to make the appropriate adjustments)
(2) Flip / reset accuracy: ± 3 °
(3) automatic weighing: 0 ~ 30g ~ 100g continuous weighing
(4) PLC controls the display: 0 ~ 15s ~ 1min ~ 2min
(5) pass / fail alarm, automated fuel management system , print.
(6) operating platform rotates security features.
(7) Drain cup electronic positioning system
(2) Flip / reset accuracy: ± 3 °
(3) automatic weighing: 0 ~ 30g ~ 100g continuous weighing
(4) PLC controls the display: 0 ~ 15s ~ 1min ~ 2min
(5) pass / fail alarm, automated fuel management system , print.
(6) operating platform rotates security features.
(7) Drain cup electronic positioning system
2015年5月14日星期四
The fourth tank gauging system test platform
Fuel tank tightness test station. Specific technical requirements refer QC / T 644-2000 industry standards relevant content 4.5. Test methods refer QC / T 644-2000 industry standard 5.3. The system adopts PLC control, submersible fuel pump underwater leak box is easy to detect high-intensity lighting. Water circulation filtration system alternative, diesel pump manufacturers .
2015年5月11日星期一
The second tank gauging system test platform
Fuel tank pressure test, gas station dispensers , the valve opening pressure test and fuel tank inlet valve opening pressure test rig. Safety fuel tank pressure test requirements of 3.6, 3.7 reference GB18296-2001 national standards, test methods reference GB18296-2001 national standards 4.4, 4.5 items.
Fuel tank pressure test points test two tests and a metal tank plastic tank. Plastic fuel tank pressure test temperature is very warm. Automatic pressurization system with proportional valve control, fuel dispensing nozzles , water flow control device to control the use of implantation rated capacity. After two trials normal temperature.
Fuel tank pressure test points test two tests and a metal tank plastic tank. Plastic fuel tank pressure test temperature is very warm. Automatic pressurization system with proportional valve control, fuel dispensing nozzles , water flow control device to control the use of implantation rated capacity. After two trials normal temperature.
2015年5月7日星期四
The first tank system test platform
The test platform for the fuel tank cover seal test bench. Technical requirements refer QC / T 644-2000 industry standards 4.6 items, safety performance requirements reference GB18296-2001 National Standard 3.1, fuel dispensing pump , test methods refer QC / T 644-2000 5.4 industry standards and national GB18296-2001 standard 4.1.
After the tank is fixed onto the rotary table fixture, in the case of no-load electric flip station tank through 180 degrees, the level of two-dimensional control by the motor will drain cup positioned below the fuel tank cover. Then flip the tank return. Through traffic control device after loading the rated amount of water seal, electronic fuel dispenser the tank through the motor and reducer drive platform rotated 180 degrees, will be stable after 15 seconds in one minute leak peeled weighing control by PLC.
Platform flip back position, then release clip Kaifeng pumping and drain cup rises automatically drained leakage. Users can capture leakage through the computer's weight, print the test results, mechanical fuel level gauge the proposed increase in the rotation when operating platform security features.
After the tank is fixed onto the rotary table fixture, in the case of no-load electric flip station tank through 180 degrees, the level of two-dimensional control by the motor will drain cup positioned below the fuel tank cover. Then flip the tank return. Through traffic control device after loading the rated amount of water seal, electronic fuel dispenser the tank through the motor and reducer drive platform rotated 180 degrees, will be stable after 15 seconds in one minute leak peeled weighing control by PLC.
Platform flip back position, then release clip Kaifeng pumping and drain cup rises automatically drained leakage. Users can capture leakage through the computer's weight, print the test results, mechanical fuel level gauge the proposed increase in the rotation when operating platform security features.
2015年5月4日星期一
Fuel tank leak detection equipment, production lines acclaim
The company in 2001 for the German KOTAS manufactures a fuel tank leak detection equipment C6 Audi production line, fuel card management system , the use of PLC and computer intelligent automatic detection of qualified and unqualified sorting intelligent storage printing and pneumatic controls have been well received in Germany. Japan seized the wet sensor, in the case of the Japanese staff can not be timely to the site, we solved the installation.
Thus, the German side twice in person to visit our company, but also a set of customized production line leak detection PQ35 contract we completed in two months time and acceptance. For this cooperation project with your company, you will learn to make equipment for the German KOTAS system experience, mechanical fuel level gauge , combined with domestic and foreign products advantages for your company to make qualified satisfaction.
Thus, the German side twice in person to visit our company, but also a set of customized production line leak detection PQ35 contract we completed in two months time and acceptance. For this cooperation project with your company, you will learn to make equipment for the German KOTAS system experience, mechanical fuel level gauge , combined with domestic and foreign products advantages for your company to make qualified satisfaction.
2015年5月1日星期五
Tank gauging system and testing program
The system has four components can be tested as follows respectively
1, the vehicle fuel tank cap fuel tank tightness test
2, the fuel tank pressure test, safety valve opening pressure test and fuel tank inlet valve opening pressure test, mechanical fuel level gauge
3, the plastic fuel tank angle hammer impact test
4, the fuel tank tightness test.
The system meets GB18296-2001 and QC / T 644-2000 standard requirements. The system is four relatively independent test platform. automated fuel management system
1, the vehicle fuel tank cap fuel tank tightness test
2, the fuel tank pressure test, safety valve opening pressure test and fuel tank inlet valve opening pressure test, mechanical fuel level gauge
3, the plastic fuel tank angle hammer impact test
4, the fuel tank tightness test.
The system meets GB18296-2001 and QC / T 644-2000 standard requirements. The system is four relatively independent test platform. automated fuel management system
订阅:
博文 (Atom)