Third test platform of oil tank monitoring system


Plastic fuel tank angle hammer impact test station. The test reference GB18296-2001 National Standard Test Method for z in 4.6. After adding the liquid in the tank rated clamping, gas station dispensers triangular cloud by 15KG weight hammer with impact energy 30J impact Easy lesion.

Automatic height adjustment angle hammer, hammer adjustable within the angular range of 20J ~ 50J. Entire fixture platform horizontal flip vertically, horizontally to adjust the position of the pendulum. Mass position control can be divided into manual and automatic.

The tank filter media can be recovered. Flow control means for controlling the use of water injection rated capacity. The entire test rig can move, automatic fuel dispenser test supporting peripherals used with the check.